ib-loconet-en
Intellibox in LocoNet mode
Overview
- LocoNet devices are not reported using the p50/p50x protocol.
- Using the LocoNet protocol all devices on the LocoNet bus are accessible.
- Support is excluded because the IB does behave not conform the LocoNet specs.
Manufacturer | Uhlenbrock / Modeltreno |
Product info | ![]() |
Description | The intellibox is a full featured command station. It has a build in RS232 interface that can be operated in a "LocoNet" mode. Than it behaves similar to a LocoBuffer. |
Configuration
- Upgrade the software inside the Intellibox to at least version 1.500:
http://www.uhlenbrock.de
- Put the interface into mode "LocoNet":
- Basic settings → interface → syntax → LocoNet
- Set baud rate to 19200 Baud:
- Basic settings → interface → bit per second → 19200 bit/s
- Set the UART of the interface to 1 stop bits: (default 2)
- Basic settings → special option → SO 5 → 1
- Disable SO 6: (default 254)
- Basic settings → special option → SO 6 → 0
Additonal Info: ib-so.pdf