Inhoud → Command Stations → Tams RailCom
Component | Versie | Opmerking |
---|---|---|
Rocrail | 1.4 | revision 1337 or higher |
RC-Link | Firmware 1.1 | |
OpenDCC | Atmega32 firmware 0.23 | RailCom cutouts and CV read on the main. |
Lenz LZV100 | Firmware 3.6 | RailCom cutouts |
Lenz LI-USB | Firmware 1.7-16 | |
1) Confirmed by Lenz; Een firmware update is nodig, niet op korte termijn beschikbaar. 22-02-2010
De FTDI device driver moet geïnstalleerd zijn om RC-Link onder OS X te kunnen gebruiken.
Op de MacBook, onder OS X 10.6, is de naam:
/dev/tty.usbserial-A10048Md
The RC-Link is bind in the system without special device drivers and is most likely named as:
/dev/ttyUSB0
Check the kernel messages for the right device name.
usb 2-2: New USB device found, idVendor=0403, idProduct=6001 usb 2-2: New USB device strings: Mfr=1, Product=2, SerialNumber=3 usb 2-2: Product: FT232R USB UART usb 2-2: Manufacturer: FTDI usb 2-2: SerialNumber: A10048Md usb 2-2: FTDI USB Serial Device converter now attached to ttyUSB0 usbcore: registered new interface driver ftdi_sio
De benodigde driver kan gedownload worden als Windows deze niet ondersteunt. :
Voordat Rocrail de loc identificatie kan verwerken moet dit aangezet worden op algemeen .
Nadat de verbinding met de RC-Link tot stand is gekomen laten de volgende boodschappen de goede werking zien:
20100217.193835.095 r9999I rclinkre ORcLink 0329 SN=38 Software=1.1 Hardware=1.0 20100217.193837.013 r9999c rclinkre ORcLink 0312 detector 1 reported address 0 20100217.193837.013 r9999c rclinkre ORcLink 0312 detector 2 reported address 0 20100217.193837.013 r9999c rclinkre ORcLink 0312 detector 3 reported address 0 ...
Als alles aangesloten is volgens de fabriekshandleiding wordt het decoderadres gemeld zodra een loc het detectie spoor oprijdt. :
20100219.090833.065 r9999c rclinkre ORcLink 0312 detector 1 reported address 4958 20100219.090845.826 r9999c rclinkre ORcLink 0312 detector 1 reported address 0
<plan rocrailversion="1.4.999-1321"> <zlevel title="railcom" z="0"/> <fblist> <fb id="rcd1" x="3" y="2" z="0" state="true" prev_id="rcd1" desc="" show="true" road="false" curve="false" blockid="" routeids="" ori="west" iid="" bus="4" addr="1" activelow="false" ctciid="" ctcaddr="0" ctcport="0" ctcgate="0" ctcasswitch="false" identifier="4958"/> </fblist> <bklist> <bk id="b1" x="3" y="3" z="0" reserved="false" entering="false" state="open" prev_id="b1" desc="" len="0" electrified="false" station="false" gomanual="true" acceptghost="false" terminalstation="false" wait="true" road="false" allowchgdir="true" smallsymbol="false" show="true" commuter="no" ttid="" signal="" wsignal="" signalR="" wsignalR="" speed="cruise" exitspeed="cruise" type="none" incline="0" waitmode="random" minwaittime="1" maxwaittime="30" waittime="10" mvscale="87" mvdistance="0" mvmph="false" evttimer="0" iid="" addr="0" port="0" td="false" typeperm="all"> <fbevent id="rcd1" action="ident" from="all" byroute="all" endpuls="false"/> </bk> </bklist> <lclist> <lc id="Köf" identifier="4958" addr="4958" iid="" prot="L" spcnt="128" fncnt="12" V_min="10" V_mid="50" V_max="100" V_Rmin="0" V_Rmid="0" V_Rmax="0" V_step="0" mass="0" V_mode="percent" placing="true" regulated="true" restorefx="true" dirpause="0" blockwaittime="10" evttimer="0" priority="10" usescheduletime="false" commuter="false" trysamedir="false" tryoppositedir="false" forcesamedir="false" shortin="false" inatpre2in="false" usemanualroutes="false" engine="diesel" cargo="none" secondnextblock="false" consist_lightsoff="false" consist="" V="0" throttleid=""/> </lclist> </plan>
Als het blok vrij is wordt de gemelde loc in het blok geplaatst. :
20100220.162810.365 r9999c rclinkre ORcLink 0318 detector [1] reported address [3] state [on] direction [right] 20100220.162810.366 r9999W rclinkre OBlock 0312 locId not set in block b1 20100220.162810.366 r9999I rclinkre OLoc 1695 cmd "block" for Talent. 20100220.162810.366 r9999I rclinkre OBlock 1510 b1 locid=Talent 20100220.162810.366 r9999I rclinkre OBlock 1531 b1 state=open 20100220.162810.366 r9999I rclinkre OBlock 1462 init block b1
In dit voorbeeld wordt de Talent met ID "3" in blok b1 geplaatst.
Als het gebruikte CS het lezen van CV's op het hoofdspoor ondersteunt , zoals OpenDCC, dan wordt de CV waarde door de RC-link gerapporteerd:
20100220.140925.442 r9999c rclinkre ORcLink 0348 detector 1 reported CV value 93
Deze waarden worden in Rocview getoond.