All boosters defined in the layout files are controlled by the Power Manager.
If a (modular) layout has more than one booster it will be easier to locate power problems like short circuits.
With modular layouts the benefit is clear when logical clusters of modules have their own booster.
If the Booster can report its power state the listed blocks will use this flag at reservation.
A reservation will be rejected if the Booster power is off.
All linked modules and blocks will get a red background in case of a short circuit detected event.
This picture shows a short circuit in block 2. The block will get a yellow background, depending of the active theme, but the label will remain unchanged.
This picture shows a short circuit in block 2 and module m1.
Add a new boosteer to the list.
Delete the selected booster. With the Undo dialog it can be retrieved in the same session.
All text fields which are marked with a @ can open the @Box by a single click on its label if the text field is not empty. The text field contents will be used to do a find. |
The booster identifier.
Free text to describe this booster.
Interface identifier.
A brief description of the power district.
The short circuit sensor generates an event on when it is detected and when it is cleared.
This ID should be defined in the sensor table.
An event is raised when the track power state did change.
This ID should be defined in the sensor table.
Blocks can check the power state before accepting a reservation.
The power manager uses this output to control track power.
This ID should be defined in the output table.
The decimal Unique-ID number of the booster or occupancy detection. (BiDiB)
The Short circuit/Power sensor and the Power output are not used and can be left empty.
Booster bus and address in the connected Command Station.
Supported CS:
If the Rocview should be able to show power events the Blocks, Staging Blocks, Fiddle Yards and Turntables in this power district must be add to the list.
This has also impact on the reservation if the Booster is able to report power state by sensor or software report.
Power on the booster after a short circuit has been cleared.
This flag is used in case the booster is able to report its state. (BiDiB UID)
Blocks can check the power state before accepting a reservation.
Track power control buttons for the selected booster.
Reset the min/max values of the selected booster to zero.1)
History log size in minutes.
Use the full width for the samples.