This central station is a follow-up from WIO_Prog1.
Since most central station now are working with a dc power supply, that is needed for this one too.
With two built-in 3,5Amp output drivers, one will have a to use these outputs together on your
railroad tracks, both wih their own section.
In that case you are not working with 7 Amp power on the rails, but with two sections with 3,5 Amp each.
The ouput is electronically fused, so short circuit will imediate switch off total power.
WIO_prog2 can be controlled from Rocrail via WIFI, USB and CAN.
The used firmware is the same firmware as for all WIO units, using Lolin D1 or D32 (Arduino related) modules.
DCC Locomotives must be set IID to WIO and Node-ID to the ID of the WIO-Prog2.
Since this board is using same firmware as other WIO related units, the complete concept
is explained in one page.
https://wiki.rocrail.net/doku.php?id=arduino:wio-en
The schematics |
part positions on pcb |
bill of materials |
Firmware for IC3 (PICSimulator16) (coming up) |
JP1 | Maximum current selector |
---|---|
1-2 connected | short circuit > 3.5 Amp |
2-3 connected | short circuit > 1 Amp |
JP2 + JP3 | IIC pull up for bus driver |
---|---|
1-2 connected | P82B715 installed I2C is buffered for longer line (> 1 meter) |
2+3 connected | P82B715 not installed I2C is directly connected to RocNet |
JP4 CAN bus terminator |
---|
set this jumper when CAN bus is used, and this unit is at one of the ends of the CAN line |