Line 1: | Line 1: | ||
- | ====== GCA101v2: LocoBuffer-UDP ====== | + | ====== GCA101v2: LocoBuffer |
[[english|{{ | [[english|{{ | ||
[[english|Content]] -> [[hardware-en|Hardware]] -> [[hardware-en# | [[english|Content]] -> [[hardware-en|Hardware]] -> [[hardware-en# | ||
Line 5: | Line 5: | ||
|< >| | |< >| | ||
- | | {{:: | + | | {{:: |
- | ^ Hardware | + | ^ Hardware |
+ | ^ Firmware TCP ^ Dani Guisado | | ||
+ | ^ Firmware UDP ^ Robert Evers & Fred Jansen | | ||
\\ | \\ | ||
Line 88: | Line 90: | ||
\\ | \\ | ||
+ | |||
+ | ==== LED Signaling==== | ||
+ | ^ LED ^ Function | ||
+ | | 1 | Power supply indication | ||
+ | | 2 | 3.3 Volt power indication | ||
+ | | 3 | LocoNet activity | ||
+ | | 4 | Ethernet activity | ||
+ | |||
+ | \\ | ||
==== Jumper settings ==== | ==== Jumper settings ==== | ||
Line 109: | Line 120: | ||
Firmware is developed in Spain by Dani Guisado and downloadable here: https:// | Firmware is developed in Spain by Dani Guisado and downloadable here: https:// | ||
Website of Dani is also very interesting | Website of Dani is also very interesting | ||
- | Leds blink when waiting for a connection from Rocrail.\\ | + | LEDs blink when waiting for a connection from Rocrail.\\ |
- | When Rocrail is connected, | + | When Rocrail is connected, |
Standard Ethernet address: 192.168.0.200.\\ | Standard Ethernet address: 192.168.0.200.\\ | ||
Other IP addres can be pre-programmed in INO file before programming the chip.\\ | Other IP addres can be pre-programmed in INO file before programming the chip.\\ | ||
Line 123: | Line 134: | ||
=== Rocrail setup === | === Rocrail setup === | ||
Communication needs to be set as LbServer in Rocrail settings > controller: | Communication needs to be set as LbServer in Rocrail settings > controller: | ||
- | {{:gca:controller_setting.jpg}} | + | {{:gca:gca101-tcp-setup-en.png?400}} |
- | |||
- | === LED Signalling=== | ||
- | ^ GCA101v2 board ^^^ | ||
- | | LED1 | supply power indication | ||
- | | LED2 | 3.3 Volt power indication | ||
- | | LED3 | Loconet activity | ||
- | | LED4 | Ethernet activity | ||
- | |||
- | \\ | ||
==== UDP ==== | ==== UDP ==== | ||
- | [[http:// | + | === Files === |
{{: | {{: | ||
- | |||
- | Thanks to Robert Evers & Fred Jansen who have put much energy in getting the system up and running, you will finally be able to run Rocrail and Loco-I/O without USB and/or RS232.\\ | ||
- | |||
- | |||
- | === Led signalling=== | ||
- | ^ GCA101v2 board ^^^ | ||
- | | LED1 | supply power indication | ||
- | | LED2 | 3.3 Volt power indication | ||
- | | LED3 | Loconet activity | ||
- | | LED4 | Ethernet activity | ||
- | \\ | ||
=== Rocrail Setup=== | === Rocrail Setup=== |