mgv101v2-en
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
mgv101v2-en [2025/08/30 14:43] – rjversluis | mgv101v2-en [2025/08/30 15:38] (current) – rjversluis | ||
---|---|---|---|
Line 1: | Line 1: | ||
- | ====== GCA101v2: LocoBuffer-UDP ====== | + | ====== GCA101v2: LocoBuffer |
[[english|{{ | [[english|{{ | ||
[[english|Content]] -> [[hardware-en|Hardware]] -> [[hardware-en# | [[english|Content]] -> [[hardware-en|Hardware]] -> [[hardware-en# | ||
* [[mgv-overview-en|The GCA modules]] | * [[mgv-overview-en|The GCA modules]] | ||
- | {{:: | + | |< >| |
- | + | | | |
- | ^ Hardware | + | ^ Hardware |
+ | ^ Firmware TCP ^ Dani Guisado | | ||
+ | ^ Firmware UDP ^ Robert Evers & Fred Jansen | | ||
\\ | \\ | ||
===== Introduction ===== | ===== Introduction ===== | ||
- | [[http://en.wikipedia.org/ | + | The [[mgv101-en|GCA101v1]] was ready for an update.\\ |
- | GCA101v1 | + | |
Since DC power supplies are getting cheaper, this unit does not need a special on-board power supply.\\ | Since DC power supplies are getting cheaper, this unit does not need a special on-board power supply.\\ | ||
So the new design is smaller and fitted with a very compact and good quality switching regulator for the 3.3V.\\ | So the new design is smaller and fitted with a very compact and good quality switching regulator for the 3.3V.\\ | ||
Line 19: | Line 20: | ||
===== Features ===== | ===== Features ===== | ||
- | [[http:// | + | * UDP or TCP connection |
* Solid GCA-Compatible power supply | * Solid GCA-Compatible power supply | ||
* Isolated coupling between PC and Ethernet | * Isolated coupling between PC and Ethernet | ||
Line 32: | Line 33: | ||
===== Power supply ===== | ===== Power supply ===== | ||
- | Only dc power is allowed.\\ | + | Only DC power is allowed.\\ |
- | Power supply : 12Vdc minimum | + | Power supply : 12VDC minimum |
- | GCA can provide you with a good and small 230V to 12Vdc supply.\\ | + | GCA can provide you with a good and small 230V to 12VDC supply.\\ |
Please refer to pricelist.\\ | Please refer to pricelist.\\ | ||
| | ||
Line 42: | Line 43: | ||
The GCA101 is equipped with a special Ethernet connector.\\ | The GCA101 is equipped with a special Ethernet connector.\\ | ||
It provides an electric isolation , which means that computer and your trains are not electrically connected together.\\ | It provides an electric isolation , which means that computer and your trains are not electrically connected together.\\ | ||
- | The standard Ethernet cable can be one of the two types. Either normal or ' | ||
\\ | \\ | ||
Line 50: | Line 50: | ||
If you do not like this situation, use a dedicated cheap router for it.\\ | If you do not like this situation, use a dedicated cheap router for it.\\ | ||
Direct connection GCA101 to PC is possible but requires some experience with networking.\\ | Direct connection GCA101 to PC is possible but requires some experience with networking.\\ | ||
+ | |||
+ | ===UDP notes === | ||
One important mark to old left-over routers:\\ | One important mark to old left-over routers:\\ | ||
- | Routers previously used at home with your previous Internet/ | + | Routers previously used at home with your previous Internet/ |
This is probably caused by the UDP channel inside the router, which should be opened by passwords/ | This is probably caused by the UDP channel inside the router, which should be opened by passwords/ | ||
- | In this case, that router is unuseable.\\ | + | In this case, that router is unusable for UDP communication.\\ |
One other problem might cause no connection in Windows.\\ | One other problem might cause no connection in Windows.\\ | ||
- | The ethernet | + | The Ethernet |
In that case Windows sometimes has a problem to decide where LocoNet communication should be sent to.\\ | In that case Windows sometimes has a problem to decide where LocoNet communication should be sent to.\\ | ||
Best way to solve this, is tot find out which inside ethernet adapters are not used, and shut them off in Windows.\\ | Best way to solve this, is tot find out which inside ethernet adapters are not used, and shut them off in Windows.\\ | ||
Line 88: | Line 90: | ||
\\ | \\ | ||
+ | |||
+ | ==== LED Signaling==== | ||
+ | ^ LED ^ Function | ||
+ | | 1 | Power supply indication | ||
+ | | 2 | 3.3 Volt power indication | ||
+ | | 3 | LocoNet activity | ||
+ | | 4 | Ethernet activity | ||
+ | |||
+ | \\ | ||
==== Jumper settings ==== | ==== Jumper settings ==== | ||
Line 104: | Line 115: | ||
===== Firmware ===== | ===== Firmware ===== | ||
- | ==== Firmware | + | ==== TCP ==== |
GCA101 also can be used with TCP.\\ | GCA101 also can be used with TCP.\\ | ||
Processor should be changed to ATmega328P.\\ | Processor should be changed to ATmega328P.\\ | ||
Firmware is developed in Spain by Dani Guisado and downloadable here: https:// | Firmware is developed in Spain by Dani Guisado and downloadable here: https:// | ||
Website of Dani is also very interesting | Website of Dani is also very interesting | ||
- | Leds blink when waiting for a connection from Rocrail.\\ | + | LEDs blink when waiting for a connection from Rocrail.\\ |
- | When Rocrail is connected, | + | When Rocrail is connected, |
Standard Ethernet address: 192.168.0.200.\\ | Standard Ethernet address: 192.168.0.200.\\ | ||
Other IP addres can be pre-programmed in INO file before programming the chip.\\ | Other IP addres can be pre-programmed in INO file before programming the chip.\\ | ||
Line 123: | Line 134: | ||
=== Rocrail setup === | === Rocrail setup === | ||
Communication needs to be set as LbServer in Rocrail settings > controller: | Communication needs to be set as LbServer in Rocrail settings > controller: | ||
- | {{:gca:controller_setting.jpg}} | + | {{:gca:gca101-tcp-setup-en.png?400}} |
- | === LED Signalling=== | + | ==== UDP ==== |
- | ^ GCA101v2 board ^^^ | + | === Files === |
- | | LED1 | supply power indication | + | |
- | | LED2 | 3.3 Volt power indication | + | |
- | | LED3 | Loconet activity | + | |
- | | LED4 | Ethernet activity | + | |
- | + | ||
- | \\ | + | |
- | + | ||
- | ==== UDP Multicast | + | |
{{: | {{: | ||
- | |||
- | Thanks to Robert Evers & Fred Jansen who have put much energy in getting the system up and running, you will finally be able to run Rocrail and Loco-I/O without USB and/or RS232.\\ | ||
- | |||
- | |||
- | === Led signalling=== | ||
- | ^ GCA101v2 board ^^^ | ||
- | | LED1 | supply power indication | ||
- | | LED2 | 3.3 Volt power indication | ||
- | | LED3 | Loconet activity | ||
- | | LED4 | Ethernet activity | ||
- | \\ | ||
=== Rocrail Setup=== | === Rocrail Setup=== |
mgv101v2-en.1756557806.txt.gz · Last modified: 2025/08/30 14:43 by rjversluis