gca173-en
Differences
This shows you the differences between two versions of the page.
| Next revision | Previous revision | ||
| gca173-en [2023/05/14 15:11] – created - external edit 127.0.0.1 | gca173-en [2025/11/03 17:03] (current) – [Connection Hall sensor] phg | ||
|---|---|---|---|
| Line 8: | Line 8: | ||
| ^^^^By Peter Giling ^^^^ | ^^^^By Peter Giling ^^^^ | ||
| - | | This Unit is **NOT** 3V3 compatible | + | | |
| Line 90: | Line 90: | ||
| \\ | \\ | ||
| - | ===== One other interesting option with these sensors: | + | ===== One new interesting option with GCA173 |
| - | Using Loc-combinations, | + | Real simulation of railroad crossing |
| - | The use of two magnets | + | But many grandfathers might let there grandson or granddaugther play manual with their fantastic setup.\\ |
| + | In that case, the railroad needs manual control as well, which might be a bit difficult to do.\\ | ||
| + | positioning the turnouts might be already sometimes a step too far.\\ | ||
| + | Now for this GCA173 there is nice task available to control railroad crossing, totally autonomic.\\ | ||
| + | There are several options possible: | ||
| + | * a single track, | ||
| + | * a single track, used for both directions. | ||
| + | * a double track, where trains can pass in both directions. | ||
| + | All of these options are possible with a GCA173 with special firmware.\\ | ||
| + | An explanation | ||
| \\ | \\ | ||
| Line 116: | Line 125: | ||
| ^ Type ^ Size ^ | ^ Type ^ Size ^ | ||
| - | | 1 | | + | | 1 | |
| - | | 2 | | + | | 2 | |
| - | | 3 | | + | | 3 | |
| - | | 4 | | + | | 4 | |
| | 5 | Disc 5mm ∅ high 3 mm | | | 5 | Disc 5mm ∅ high 3 mm | | ||
| | 6 | Cube 5mm | | | 6 | Cube 5mm | | ||
| Line 149: | Line 158: | ||
| The connection wires between Hallsensor and GCA173 can be up to 6' or 2 meter.\\ | The connection wires between Hallsensor and GCA173 can be up to 6' or 2 meter.\\ | ||
| Please be careful not to feed those wires parallel with rails and rail wires.\\ | Please be careful not to feed those wires parallel with rails and rail wires.\\ | ||
| - | A bit of twisting these wires will inprove protection to any distorsion.\\ | ||
| If that is inevitable, keep a distance of 4'' | If that is inevitable, keep a distance of 4'' | ||
| + | A bit of twisting these wires will inprove protection to any distorsion.\\ | ||
| Straight angle crossing is no problem.\\ | Straight angle crossing is no problem.\\ | ||
| Below you can download a drawing of hallsensor connection.\\ | Below you can download a drawing of hallsensor connection.\\ | ||
| Line 159: | Line 168: | ||
| ===== Connection to reed-switch ===== | ===== Connection to reed-switch ===== | ||
| - | Allthough GCA173 can work fine with reed-switch as wel, the option for wheel counter is NOT applicable.\\ | + | Allthough GCA173 can work fine with reed-switch as well, the option for wheel counter is NOT applicable.\\ |
| This due to the fact the the number of pulses, generated on the passing of a magnet is never the same, and unpredictable.\\ | This due to the fact the the number of pulses, generated on the passing of a magnet is never the same, and unpredictable.\\ | ||
| {{: | {{: | ||
| Line 188: | Line 197: | ||
| ^N.B. Self made pc-boards are not supported! ^ | ^N.B. Self made pc-boards are not supported! ^ | ||
| \\ | \\ | ||
| + | \\ | ||
| + | ^ Housing is only for DIY 3D printing. | ||
| + | | {{ : | ||
| + | \\ | ||
| ===== Firmware ===== | ===== Firmware ===== | ||
| {{: | {{: | ||
| Line 194: | Line 206: | ||
| Timing is close to 80 mSec.\\ | Timing is close to 80 mSec.\\ | ||
| {{: | {{: | ||
| - | Version 1_5 has a better startup sequence. It will send all actual sensor positions\\ | + | Version 1_5 has a better startup sequence. It will initial |
| ===== Pictures from satisfied customers ===== | ===== Pictures from satisfied customers ===== | ||