can-gca2-en
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
can-gca2-en [2025/05/15 16:16] – [The pcboard] phg | can-gca2-en [2025/05/15 16:21] (current) – [Reed switches and hall sensors] phg | ||
---|---|---|---|
Line 1: | Line 1: | ||
====== CAN-GC2 Universal 16 port I/O node for CANBUS ====== | ====== CAN-GC2 Universal 16 port I/O node for CANBUS ====== | ||
[[english|{{ | [[english|{{ | ||
- | [[: | + | [[: |
* [[: | * [[: | ||
* [[: | * [[: | ||
Line 14: | Line 14: | ||
the CAN-GC2 can be mixed with GCA50 units on the same cable, but of course need different computer interfaces.\\ | the CAN-GC2 can be mixed with GCA50 units on the same cable, but of course need different computer interfaces.\\ | ||
The also available CAN-GC3 will bring a complete solution for DCC Model Railroading in DIY. \\ | The also available CAN-GC3 will bring a complete solution for DCC Model Railroading in DIY. \\ | ||
- | The CAN-GC1e connects the computer with the CAN bus. All the well known MGV*/GCA* satellite boards are compatible | + | The CAN-GC1e connects the computer with the CAN bus. All the well known MGV*/GCA* satellite boards are useable |
Line 45: | Line 45: | ||
| {{ : | | {{ : | ||
\\ | \\ | ||
- | ^ N.B. Only complete ordered kits will be supported! ^ | + | ^ N.B. Only complete ordered kits will be supported! |
+ | ^ Housing is only for DIY. | ||
\\ | \\ | ||
=== Previous version (blue pc-board) === | === Previous version (blue pc-board) === | ||
Line 116: | Line 117: | ||
Read switches and hall sensors can be used as feed-back sensors.\\ | Read switches and hall sensors can be used as feed-back sensors.\\ | ||
However, since the contact information inside the CAN-GC2 is arranged so that the unit is\\ | However, since the contact information inside the CAN-GC2 is arranged so that the unit is\\ | ||
- | low sensitive for distorsions, | + | low sensitive for distorsions, |
In addition to that, reed-contacts usually give more than 1 pulse when activated, known as ' | In addition to that, reed-contacts usually give more than 1 pulse when activated, known as ' | ||
For this way of sensoring, a special pulse-extender is available. See __**[[gca173-en|Hall sensor and reed switch unit]]**__\\ | For this way of sensoring, a special pulse-extender is available. See __**[[gca173-en|Hall sensor and reed switch unit]]**__\\ |
can-gca2-en.1747318572.txt.gz · Last modified: 2025/05/15 16:16 by phg